Cryogenic Storage for Hazardous Liquefied Gases

Storing hazardous gases in liquefied state at cryogenic temperatures requires exceptionally high standards to ensure containment integrity, thermal stability, and compliance with the strictest regulatory requirements. Roben Mfg, Inc. specializes in producing custom cryogenic storage systems that meet the exacting needs of industries working with hazardous liquefied gases, from specialized research applications to large-scale industrial operations.

Our cryogenic storage systems for hazardous liquefied gases are engineered to exceed the highest industry standards, including ASME, CGA, and specialized cryogenic codes. These systems provide uncompromising thermal efficiency, advanced insulation technology, and superior safety features necessary for the most challenging cryogenic applications.

Types of Cryogenic Storage Systems

  • Vacuum-Jacketed Cryogenic Storage Vessels
  • Liquefied Natural Gas (LNG) Storage Systems
  • Liquid Oxygen Storage Containers
  • Liquid Hydrogen Storage Systems
  • Liquefied Toxic Gas Dewars
  • Ultra-Cold Chlorine Storage Vessels
  • Cryogenic Transport Containers
  • Multi-Layered Insulated Storage Tanks
  • Super-Insulated Portable Containers
  • Low-Temperature Process Vessels
  • Cryogenic Sample Storage Systems
  • Hazardous Gas Liquefaction Equipment
  • Cryogenic Flow Control Systems
  • Low-Temperature Research Dewars
  • High-Capacity Industrial Cryogenic Tanks

Key Features

  • Advanced Vacuum Insulation: Multi-layer super insulation with vacuum-jacketed design
  • Specialized Cryogenic Valves: Low-temperature valves designed for hazardous service
  • Low-Temperature Materials: Materials specifically selected for cryogenic service
  • Pressure Management Systems: Integrated pressure relief and control systems
  • Redundant Level Monitoring: Multiple systems for accurate content measurement
  • Specialized Venting Systems: Engineered vent systems for safe pressure management
  • Thermal Stratification Prevention: Designs that minimize thermal gradients
  • Comprehensive Documentation: Material certificates, testing records, and validation documentation

Applications

  • Industrial Gas Manufacturing
  • Semiconductor Processing
  • Healthcare and Medical Applications
  • Energy Storage and Transport
  • Specialized Chemical Processing
  • Advanced Research Facilities
  • Aerospace Applications
  • Alternative Fuel Management
  • Defense and Military Operations
  • Environmental Monitoring
  • Pharmaceutical Manufacturing
  • Food Freezing and Preservation
  • Superconductivity Research
  • Cryogenic Sample Preservation
  • Metallurgical Processing
  • Particle Physics Research
  • MRI and Imaging Systems
  • Specialized Transportation
  • Emergency Response Systems
  • Low-Temperature Research

Industries Served

  • Industrial Gas Suppliers
  • Semiconductor Manufacturing
  • Healthcare Institutions
  • Energy Sector
  • Chemical Manufacturing
  • Research Institutions
  • Aerospace Industry
  • Defense Contractors
  • Pharmaceutical Companies
  • Food Processing Industry
  • Electronics Manufacturing
  • Transportation Services
  • Medical Equipment Suppliers
  • Specialized Laboratories
  • University Research Facilities

Compliance and Standards

Design Codes

  • ASME Boiler and Pressure Vessel Code Section VIII
  • ASME B31.3 Process Piping Code
  • Compressed Gas Association (CGA) Standards
  • International Cryogenics Safety Code

Industry Standards

  • NFPA 55 Compressed Gases and Cryogenic Fluids Code
  • ISO 21009 Cryogenic Vessels
  • European Standards EN 13458 for Static Vacuum Insulated Vessels
  • PED 2014/68/EU Pressure Equipment Directive Where Applicable

Regulatory Compliance

  • Occupational Safety and Health Administration (OSHA) Requirements
  • Environmental Protection Agency (EPA) Regulations
  • Department of Transportation (DOT) for Transportable Systems
  • State and Local Cryogenic Material Regulations

Material Standards

  • ASTM standards for cryogenic materials
  • Impact testing requirements for low-temperature service
  • Special material requirements for specific gas compatibility
  • Enhanced testing for thermal cycling resistance

Testing Requirements

  • 100% Vacuum Testing of Insulation Systems
  • Specialized Leak Detection at Cryogenic Temperatures
  • Thermal Performance Verification
  • Extended Hold-Time Testing
  • Pressure Relief System Certification

Documentation and Validation

  • Material Test Reports (MTRs)
  • Vacuum Testing Certification
  • Thermal Performance Documentation
  • Pressure Relief Certification
  • Quality Control Documentation

Quality Assurance

  • Complete Material Traceability: Full documentation from raw material to finished system
  • Validated Manufacturing Processes: Specialized procedures for cryogenic service
  • Comprehensive Inspection Protocol: Multiple inspection points throughout fabrication
  • Enhanced Testing Regime: Thermal and pressure testing beyond standard requirements
  • Detailed Documentation Package: Complete records for regulatory compliance and safety verification

Custom Design Services

  • Thermal Analysis: Comprehensive evaluation of insulation requirements
  • Boil-Off Rate Optimization: Design refinements to minimize product loss
  • Custom Piping Design: Specialized piping systems for specific applications
  • Instrumentation Integration: Custom monitoring and control systems
  • Regulatory Navigation Support: Guidance through complex regulatory frameworks
  • Installation Planning: Site-specific design considerations and requirements

Contact Information

For more information on our cryogenic storage systems for hazardous liquefied gases or to discuss your specific requirements, please contact our specialized equipment specialists:

Roben Mfg, Inc.
760 Vassar Ave.
Lakewood, NJ 08701
Phone: (732) 364-6000
Email: sales@robenmfg.com
Website: https://robenmfg.com

Request a Consultation with our specialized equipment engineering team to discover how our custom cryogenic storage systems can enhance your hazardous liquefied gas management requirements.

Ask A Question

Fields Marked with * are required

Limit 2000 Characters


By submitting this form, you are consenting to receive marketing emails from: . You can revoke your consent to receive emails at any time by using the SafeUnsubscribe® link, found at the bottom of every email. Emails are serviced by Constant Contact