Fire Water Storage Tanks

Roben, Mfg, Inc. is a trusted provider of fire water storage tanks, offering rugged, code-compliant storage solutions to ensure reliable water availability during fire protection emergencies.

Our fire water tanks are engineered for maximum durability, quick deployment, and compatibility with fire suppression systems, helping facilities across industries safeguard personnel, property, and operations.

What is a Fire Water Storage Tank?

A fire water storage tank is a dedicated reservoir designed to store water for fire protection purposes. These tanks provide an uninterrupted supply of water to fire sprinkler systems, standpipes, or fire hoses in the event of a fire. Built to strict safety and regulatory standards, fire water storage tanks are critical infrastructure in commercial, industrial, and municipal settings, ensuring readiness and compliance with fire safety codes.

Types of Fire Water Storage Tanks

  • Bolted Steel Fire Water Tanks: Modular tanks assembled on-site, offering quick installation and scalability.
  • Welded Steel Fire Water Tanks: Permanently constructed tanks with high structural integrity and long service life.
  • Fiberglass Fire Water Tanks: Lightweight, corrosion-resistant tanks ideal for harsh environments.
  • Concrete Fire Water Reservoirs: Large-capacity tanks commonly used for municipal and industrial fire protection systems.
  • Underground Fire Water Storage Tanks: Space-saving solutions for locations with aesthetic or spatial limitations.
  • Dual-Use Water Storage Tanks: Serve both fire protection and domestic/process water needs with appropriate isolation systems.
  • Insulated Fire Water Tanks: Equipped with freeze protection for use in cold climates.

Fire Water Storage Tank Specifications and Characteristics

  • Compliant with NFPA 22 and AWWA Standards
  • Capacities from 5,000 to Over 1,000,000 Gallons
  • Available in Vertical or Horizontal Configurations
  • Carbon Steel, Stainless Steel, Fiberglass, or Concrete Construction
  • Interior and Exterior Corrosion Protection Coatings
  • Seismic and Wind Load Rated Designs
  • Insulation and Heat Tracing Options
  • Tank Level Monitoring and Alarm Systems
  • Anti-Vortex Suction Outlets
  • Overfill and Overflow Protection
  • Removable Roofs or Access Hatches
  • Fire Department Connection (FDC) Ports
  • UL/FM Approved Components
  • Integrated Piping, Valves, and Backflow Prevention
  • Emergency Water Access for Firefighting Crews
  • Clean-Out Access and Inspection Ports

Fire Water Storage Tank Optional Accessories

  • Level Indicators (Mechanical or Digital)
  • High and Low Level Alarms
  • Insulation Blankets or Panels
  • Electric Heat Tracing
  • Immersion Heaters for Freeze Protection
  • Overflow Weirs and Spillways
  • Ventilation Systems and Flame Arrestors
  • Cathodic Protection Systems
  • Anti-Climb Ladders and Safety Rails
  • Platform Access Stairs
  • Remote Monitoring Systems
  • Clean-In-Place (CIP) Systems
  • Drainage Valves and Sediment Collection
  • Grounding Lugs and Lightning Protection
  • Bypass Piping for Maintenance Scenarios

Certifications for Fire Water Storage Tanks

Fire Water Storage Tanks Frequently Asked Questions (FAQs)

1. What size fire water tank do I need for my facility?

Tank sizing depends on building classification, fire risk, local fire codes, and duration of required water supply. Roben, Mfg, Inc. conducts detailed fire demand analysis to determine appropriate tank capacity based on NFPA guidelines and local authority requirements.

2. Can fire water tanks be used in freezing climates?

Yes, we offer insulation packages, heat tracing, and immersion heaters to protect tanks from freezing temperatures and ensure year-round readiness.

3. Are fire water tanks required to be UL or FM approved?

In many jurisdictions and insurance requirements, UL/FM-approved components are preferred or required. We provide UL 142/2085-compliant tanks and FM-approved fittings upon request.

4. How are fire water tanks maintained?

Routine maintenance includes visual inspections, cleaning of sediment buildup, verifying valve operation, testing alarms, and ensuring corrosion protection systems are functional. We provide access ports and CIP systems to streamline maintenance.

5. Can fire water tanks be integrated with sprinkler and hydrant systems?

Yes. Roben, Mfg, Inc. designs fire water tanks to integrate seamlessly with fire suppression systems including automatic sprinklers, standpipes, hydrants, and fire pump systems, ensuring uninterrupted emergency response capability.

Contact Roben, Mfg, Inc. today to explore our fire water storage tank solutions and enhance your facility’s fire safety infrastructure.

Ask A Question

Fields Marked with * are required

Limit 2000 Characters


By submitting this form, you are consenting to receive marketing emails from: . You can revoke your consent to receive emails at any time by using the SafeUnsubscribe® link, found at the bottom of every email. Emails are serviced by Constant Contact